CONNECTIONS ELECTRICAL
The power supply to the water heater must not be switched on until the water heater is filled with
water and a satisfactory megger reading is obtained.
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
SOLAR STORAGE TANK
The water heater must be directly connected to a 240 V 50 Hz mains power supply. The continuous power
supply to the solar control unit and the timer must be on the same circuit. A weatherproof double pole
isolating switch must be installed adjacent to and accessible from the solar storage tank, in accordance with
AS 5601 or AS/NZS 5601.1 as applicable under local regulations.
A flexible 20 mm conduit is required for the electrical cable to the solar storage tank. The conduit is to be
connected to the unit with a 20 mm terminator. Connect the power supply wires directly to the terminal block,
ensuring there are no excess wire loops inside of the cover.
The terminal block on the solar storage tank has two active connections. One active wire (marked “A”) is
required for the operation of the solar control unit and one active wire (marked “TIMER A”) is required for the
operation of the gas boosting system. The gas boosting system is switched by the timer.
Note:
It is essential the active to the solar control unit is not switched by the timer.
The timer is not weatherproof and must be installed indoors. It is recommended the timer be located in
the kitchen or laundry or other location easily seen by the householder.
Connect the hot sensor lead from the solar collectors, through the hole in the side of the air duct, to the hot
sensor cable connector adjacent to the terminal block. Fit the strain relief grommet over the hot sensor lead
and secure at the hole in the air duct.
The power consumption of the water heater is:
Component
Power
Consumption
Comments
Solar controls
14 watts
Constant load 4 Watts differential controller
6 Watts solenoid valve
4 Watts timer
Solar circulator
36 Watts
Maximum load at solar heating cycle start up
30 Watts
Average load during the solar heating cycle
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be
used to supply power to the water heater.