Rheem 60 Operations Instructions

Browse online or download Operations Instructions for Water heaters & boilers Rheem 60. Rheem 60 Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
This water heater must be installed and serviced by a qualified person.
Please leave this guide with the householder.
Owner’s Guide
and
Installation Instructions
Continuous Flow
Gas Water Heater
871, 875 Series
624, E24, E26 Models
Page view 0
1 2 3 4 5 6 ... 79 80

Summary of Contents

Page 1 - Installation Instructions

This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder. Owner’s Guide and Installation

Page 2

ABOUT YOUR WATER HEATER 10 HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY? Installation requirements are shown on pages 45 to 56. The water

Page 3 - CONTENTS

11 TEMPERATURE CONTROL CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the temperatu

Page 4

12 TEMPERATURE CONTROL – STANDARD STANDARD CONTROLLER FUNCTIONS If one or more controllers are installed, at least one must be on for

Page 5 - HOW HOT SHOULD THE WATER BE?

TEMPERATURE CONTROL – STANDARD 13 STANDARD CONTROLLER Note: water volume button, water volume operating light and water volume symbol are on the K

Page 6 - WARNING

TEMPERATURE CONTROL – STANDARD 14 TEMPERATURE SETTINGS – STANDARD CONTROLLER The temperature settings of each type of controller are: Bathroom1 &

Page 7 - MAJOR FIVE YEAR SERVICE

TEMPERATURE CONTROL – STANDARD 15 TEMPERATURE ADJUSTMENT – STANDARD CONTROLLER A controller must be on and have priority to be able to adjust the te

Page 8

TEMPERATURE CONTROL – STANDARD 16 KITCHEN CONTROLLER – STANDARD The Kitchen controller allows the user to select the temperature setting for the hot w

Page 9

TEMPERATURE CONTROL – STANDARD 17 To operate the Kitchen controller: 1. Turn off the Bathroom controller(s)  If a temperature setting is displayed

Page 10 - VICTORIAN CUSTOMERS

TEMPERATURE CONTROL – STANDARD 18 BATHROOM CONTROLLERS – STANDARD The Bathroom controller(s) allows the user to select the temperature setting for the

Page 11 - TEMPERATURE CONTROL

TEMPERATURE CONTROL – STANDARD 19 ch e c k h o t w a te r te m p e r atu r e b e f o r e u s e on of f 40 C priori ty in use 42 C pr io

Page 12

PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd, Rheem New Zealand Lim

Page 13 - STANDARD CONTROLLER

TEMPERATURE CONTROL – STANDARD 20 WATER VOLUME FUNCTION – STANDARD CONTROLLER The water volume function is designed to warn, by a beeping sound, that

Page 14

TEMPERATURE CONTROL – STANDARD 21 5. Turn off the alarm  Press the water volume button to turn off the alarm. The water volume operating light goes

Page 15

22 TEMPERATURE CONTROL – DELUXE DELUXE CONTROLLER FUNCTIONS If one or more Deluxe controllers are installed, at least one must be on or the bath fil

Page 16 - Kitchen Controller

TEMPERATURE CONTROL – DELUXE 23 bath fill water volume display panel – The selected bath fill water volume is displayed in litres on all Deluxe contro

Page 17

TEMPERATURE CONTROL – DELUXE 24 VOICE PROMPT AND OPERATING TONE The Deluxe controllers have a series of voice prompts and operating tones

Page 18 - Bathroom Controller

TEMPERATURE CONTROL – DELUXE 25 Adjusting the Volume of the Voice Prompt and Operating Tone The volume of the voice prompt and the operating tone can

Page 19

TEMPERATURE CONTROL – DELUXE 26 TEMPERATURE SETTINGS – DELUXE CONTROLLERS The temperature settings of each type of Deluxe controller are: Bathroom1

Page 20

TEMPERATURE CONTROL – DELUXE 27 TEMPERATURE ADJUSTMENT – DELUXE CONTROLLERS A controller must be on with the ACTIVE indicator displayed to be able t

Page 21 - 5. Turn off the alarm

TEMPERATURE CONTROL – DELUXE 28 KITCHEN CONTROLLER – DELUXE The Kitchen Deluxe controller allows the user to select the temperature setting for the ho

Page 22 - TEMPERATURE CONTROL – DELUXE

TEMPERATURE CONTROL – DELUXE 29 To operate the Kitchen Deluxe controller: 1. Turn off the Bathroom Deluxe controller(s)  If a temperature setting

Page 23 - BATH (l)

3 CONTENTS HOUSEHOLDER - We recommend you read pages 4 to 44. The other pages are intended for the installer but may be of interest. About Your W

Page 24

TEMPERATURE CONTROL – DELUXE 30 BATHROOM CONTROLLERS – DELUXE The Bathroom Deluxe controller(s) allows the user to select the temperature setting for

Page 25 - BATH FILL

TEMPERATURE CONTROL – DELUXE 31 To operate a Bathroom Deluxe controller: 1. Turn off the Kitchen Deluxe controller  If a temperature setting is di

Page 26

TEMPERATURE CONTROL – DELUXE 32 BATH FILL MODE The Bath Fill mode is designed to allow the water heater to deliver a selected volume of water at a sel

Page 27

TEMPERATURE CONTROL – DELUXE 33 5. Close the front panel on the Deluxe controller. 6. Turn on the Bath Fill mode  Press the BATH FILL button. On

Page 28

TEMPERATURE CONTROL – DELUXE 34 Bath Fill Mode – Explanatory Notes To operate the Bath Fill mode: 1. Turn off all Deluxe controllers  It is advise

Page 29 - 8 8 8 8

TEMPERATURE CONTROL – DELUXE 35 4. Set the bath fill water volume  Press the BATH FILL VOLUME  (up button) or the BATH FILL VOLUME  (down button)

Page 30 - Controller

TEMPERATURE CONTROL – DELUXE 36 7. Open the hot tap. The operating light will glow on all Deluxe controllers. Measurement of the water flow at th

Page 31

TEMPERATURE CONTROL – DELUXE 37 Turning Off Bath Fill Mode During Its Operation The bath fill operation can be interrupted by pressing the BATH FILL b

Page 32

TEMPERATURE CONTROL – DELUXE 38 Notes on the Bath Fill mode: The Bath Fill mode can be set, turned on and turned off at any of the Deluxe controller

Page 33 - BATH FILL button to finish”

TEMPERATURE CONTROL – DELUXE 39 Opening a Second Hot Water Tap During Bath Fill Operation The bath fill water volume is measured as the water flows

Page 34

4 ABOUT YOUR WATER HEATER WATER HEATER APPLICATION This water heater is designed for use in a single family domestic dwelling for the purpose of hea

Page 35

TEMPERATURE CONTROL – DELUXE 40 Operation of the Bath Fill mode whilst a Deluxe Controller is ACTIVE It is recommended the Bath Fill mode be set and o

Page 36 - 8. Close the hot tap

41 WATER SUPPLIES This water heater must be installed in accordance with this advice to be covered by the Rheem warranty. This wat

Page 37

42 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault, which is not

Page 38

SAVE A SERVICE CALL 43 WATER FLOW FLUCTUATES More than two or three taps in use at the same time may cause a decrease in the hot water flow from the t

Page 39

SAVE A SERVICE CALL 44 CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL During the heating cycle, it is not unusual to see water vapour clouds steaming

Page 40

45 INSTALLATION – WATER HEATER THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the wat

Page 41 - WATER SUPPLIES

INSTALLATION – WATER HEATER 46 Clearance must be allowed for servicing of the water heater. The water heater must be accessible without the use of a l

Page 42 - SAVE A SERVICE CALL

INSTALLATION – WATER HEATER 47 PIPE COVER The pipe work to the water heater can be housed within a pipe cover. A pipe cover kit (AU - Part 299848, NZ

Page 43 - WATER FLOW FLUCTUATES

INSTALLATION – WATER HEATER 48 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and w

Page 44 - ERROR CODE

INSTALLATION – WATER HEATER 49 Where a temperature limiting device is installed adjacent to the in-series gas booster, the cold water line to the temp

Page 45 - INSTALLATION – WATER HEATER

ABOUT YOUR WATER HEATER 5 GAS BOOSTING FOR A SOLAR WATER HEATER Water stored in the solar storage tank passes through the in-series gas booster when a

Page 46 - SAFE TRAY

INSTALLATION – WATER HEATER 50 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem 871 series continuous flow water heater can be installed as part of

Page 47 - MAINS WATER SUPPLY

INSTALLATION – WATER HEATER 51 Circulated Hot Water Flow and Return – Continuous Flow Gas Water Heater Circulated Hot Water Flow and Return I

Page 48 - HOT WATER DELIVERY

INSTALLATION – WATER HEATER 52 WATER TEMPERATURE DIAGRAMS Note: NZ - max outlet temperature and Kitchen Controller max setting are 55°C 87

Page 49

INSTALLATION – WATER HEATER 53 DIMENSIONS AND TECHNICAL DATA Model 871 624 871 E24 875 624 875 E24 871 E26 875 E26 Rated delivery (@ 40°C r

Page 50

INSTALLATION – WATER HEATER 54 DIMENSIONS – STANDARD CONTROLLERS Kitchen Controller (Standard) Bathroom Controller (Standard)

Page 51 - REDUCING HEAT LOSSES

INSTALLATION – WATER HEATER 55 DIMENSIONS – DELUXE CONTROLLERS Deluxe Controller – Cover Closed Deluxe Controller – Cover Open

Page 52

INSTALLATION – WATER HEATER 56 TYPICAL INSTALLATION – OUTDOOR LOCATION

Page 53

57 CONNECTIONS – PLUMBING All plumbing work must be carried out by a qualified person and in compliance with the Standard AS/NZS 350

Page 54

CONNECTIONS – PLUMBING 58 PIPE SIZES The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the m

Page 55

59 CONNECTIONS – ELECTRICAL All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rul

Page 56

ABOUT YOUR WATER HEATER 6 HOTTER WATER INCREASES THE RISK OF SCALD INJURY This water heater can deliver water at temperatures which can cause scalding

Page 57 - CONNECTIONS – PLUMBING

60 INSTALLATION – CONTROLLERS CONTROLLERS The Rheem 871 and 875 series can be installed with Rheem controllers to enable the user to control the tem

Page 58 - GAS INLET

INSTALLATION – CONTROLLERS 61 Location – The controllers must be installed in dry, shaded and clean locations. Do not install the controllers: Near

Page 59 - CONNECTIONS – ELECTRICAL

INSTALLATION – CONTROLLERS 62 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the Kitchen con

Page 60 - INSTALLATION – CONTROLLERS

INSTALLATION – CONTROLLERS 63 If it is necessary to have an exposed wiring installation, follow this procedure omitting Steps 1 and 4, and make an ope

Page 61 - KITCHEN CONTROLLER

INSTALLATION – CONTROLLERS 64 BATHROOM1 AND BATHROOM2 CONTROLLERS If only one Bathroom controller is to be installed, the standard Bathroom

Page 62

INSTALLATION – CONTROLLERS 65 Wiring installation: 1. Penetrate the wall with a 30-35 mm hole at the controller location. 2. Install the supplied ca

Page 63 - Exposed Cable

INSTALLATION – CONTROLLERS 66 CONNECTING THE CONTROLLER(S) TO THE WATER HEATER To connect the controller(s) to the water heater: 1. Ensure the electr

Page 64

67 COMMISSIONING All water heaters are tested and adjusted before dispatch from the factory, however further adjustments may become necessary becaus

Page 65

COMMISSIONING 68 Gas Inlet Test Point Pressure To check the gas inlet pressure: 1. Close any hot taps and ensure the burners are not operating.

Page 66

COMMISSIONING 69 BURNER GAS PRESSURE It is necessary to check the burner gas pressure at both the minimum and maximum operational settings. To check a

Page 67 - COMMISSIONING

ABOUT YOUR WATER HEATER 7 PRECAUTIONS Where damage to property can occur in the event of the water heater leaking, the water heater must be ins

Page 68 -  Connect the manometer

COMMISSIONING 70 Notes: If the burners extinguish and error code 11 or 12 starts to flash on the LED display:  release the MIN and adjuster button

Page 69

COMMISSIONING 71 PRESET OUTLET TEMPERATURE SETTING The factory preset outlet temperature setting of the water heater is: 871 series 624, E24, E26 mo

Page 70

COMMISSIONING 72 TO CHECK OR ADJUST THE PRESET OUTLET TEMPERATURE SETTING The temperature settings will be displayed on the LED display. The preset ou

Page 71

COMMISSIONING 73 OUTLET TEMPERATURE COMPENSATION ADJUSTMENT – 875 SERIES The maximum outlet temperature of an 875 series 624, E24 and E26 model water

Page 72

COMMISSIONING 74 Note: The preset outlet temperature setting of this water heater must be set at 48°C prior to the commencement of th

Page 73

COMMISSIONING 75 13. Repeat steps 2 to 5.  if the water temperature is still below:  48°C (if a temperature controller is to be connected), or 

Page 74 -  50°C, 51°C, 52°C

76 DRAINING THE WATER HEATER To drain the water heater: Turn off the water heater (refer to “Turn Off The Water Heater” on page 75). Open a hot

Page 75

77 This page is intentionally blank.

Page 76 - DRAINING THE WATER HEATER

78 This page is intentionally blank.

Page 77

79 RHEEM CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA AND NEW ZEALAND ONLY CONTINUOUS FLOW GAS WATER HEATERS 871, 875 SERIES, 624, E24, E26

Page 78

ABOUT YOUR WATER HEATER 8 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A Rheem 871 series continuous flow water heater can be installed as part of a ci

Page 79

RHEEM CONTINUOUS FLOW GAS WATER HEATER WARRANTY – AUSTRALIA AND NEW ZEALAND ONLY Revision Date: 2013 August (31-76284-00 ) 122475D 80 CONTINUOU

Page 80 - ) 122475D

ABOUT YOUR WATER HEATER 9 FROST PROTECTION The water heater has a frost protection system. The frost protection system will protect the water heater f

Comments to this Manuals