WATER SUPPLIES
23
-1.0
no warranty applies to a:
temperature pressure relief valve or a
water heater cylinder unless an
expansion control valve is fitted.
no warranty applies to a:
-direct (open circuit) solar collector
SATURATION INDEX (SI)
SOLAR WATER HEATERS - INTANK GAS BOOST
WITHIN WARRANTY
SPECIFICATION
SATURATION INDEX
(calculated @ 80°C water temperature)
no warranty applies to a:
-direct (open circuit) solar collector
+0.4 +0.80
very corrosive very scaling
scaling
corrosive
SUMMARY OF WATER CHEMISTRY ADVICE AFFECTING WARRANTY
The water heater, solar collectors and their components are not suitable for certain water chemistries. Those
chemistries are listed below. If the water heater is connected at any time to a water supply with the following
water chemistry, the Rheem warranty will not cover any resultant faults on the components listed below:
Total Dissolved Solids (TDS) > 2500 mg/L
Total Dissolved Solids (TDS) not suitable for anode type
Saturation Index (SI) < -1.0
Saturation Index (SI) > +0.4
(if an expansion control valve is not fitted)
water heater cylinder
temperature pressure relief valve
Saturation Index (SI) > +0.8