Gas Valve LED Codes
CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety devices.
Refer repairs to qualified service personnel.
LCD CODE
For Optional
Display
GAS VALVE
LED
STATUS/PROBLEM PROBABLE CAUSE SOLUTION
None
Short ash once
every four seconds
IDLE (no call for heat,
no fault conditions)
Temperature setpoint achieved and
burner is off
No solution required
None
“Heartbeat”, alter-
nates bright/dim
Call For Heat (no fault
conditions)
Water temperature is below setpoint and
burner is on
No solution required
12
One Flash, three
second pause
Low ame signal
(control continues to
operate)
Pilot tube restriction, carbon buildup
on electrode, pilot wire damage or gas
supply
1. Gas supply pressure is low
2. Low voltage supply
3. Pilot replacement
44
Two Flash, three
second pause.
Pressure switch failed
closed
Pressure switch tube blockage or faulty
pressure switch.
1. Pressure switch wiring incorrect
2. Replace pressure switch
3. Replace tube or clear blockage.
46
Three Flash, three
second pause
Pressure switch failed
open.
Vent blockage or improper installation,
switch tube blockage, faulty switch,
blower improper operation or tempera-
ture switch open
1. Pressure switch wiring incorrect
2. Replace pressure switch
3. Air intake or exhaust obstructed
4. Replace blower temperature switch
5. Replace blower
31
Four Flash, three
second pause
TCO limit lockout
Thermal well fault, gas control fault or
tank is not lled with water
1. Reset valve and check for proper
valve cycling
2. Make sure tank is full of water
14
Five Flash, three
second pause
Flame out of sequence
Pilot or burner valve has failed open 1. Replace gas valve control
11
Six-One Flash,
three second pause
Failed trial for ignition
Insufcient gas supply, unstable pilot,
carbon buildup on electrode or wire/pilot
tube damage
1. Check gas supply
2. Replace pilot
45
Six-Two Flash,
three second pause
Recycle limit - PS/limit
opened
Vent blockage or improper installation,
switch tube blockage, faulty switch,
blower improper operation, blower tem-
perature switch open or excessive wind
at vent termination
1. Pressure switch wiring incorrect
2. Replace pressure switch
3. Air intake or exhaust obstructed
4. Replace blower temperature switch
5. Replace blower
6. Check for vent termination compli-
ance as stated in this manual
13
Six-Three Flash,
three second pause
Recycle limit - ame
lost
Pilot tube restriction, low gas supply
pressure, carbon buildup on electrode,
wire/pilot tube damage or combustion air
port blockage
1. Gas supply pressure is low
2. Jacket air holes obstructed
3. Pilot replacement
14
Six-Four Flash,
three second pause
Soft Lockout - ame
out of sequence sensed
Valve stuck in open position 1. Replace gas valve control
10
Six - Five Flash,
three second pause
Failed Ignition Lockout
Insufcient gas supply , pilot damage or
gas valve damage
1. Check gas supply
2. Replace pilot
3. Replace gas valve
47
Seven Flash, three
second pause
Flammable vapor sen-
sor lockout
Gasoline or other ammable gas was
detected near the appliance or the sensor
has failed
1. Verify no gasoline or ammable
vapors are present
2. Reset control using ON/OFF switch
on the gas control valve
3. Replace the ammable vapor sensor
49
Eight-One Flash,
three second pause
FVS fault detected
Flammable vapor sensor resistance is out
of range, wiring to FV sensor is faulty or
control is faulty
1. Replace FV sensor
2. Replace FV sensor wiring
3. Replace gas control valve
89
Eight-Two Flash,
three second pause
Temperature sensor
fault detected
Thermal well fault
1. Check thermal well wiring con-
nection
2. Replace thermal well
15
Eight-Three Flash,
three second pause
Electronics fault de-
tected
Thermal well fault or gas control fault
1. Replace gas control valve
2. Replace thermal well
93
Eight-Four Flash,
three second pause
Valve fault detected
Gas control valve needs to be reset or has
been damaged
1. Cycle power to gas control valve
2. Replace gas control valve
Page view 40