Rheem S GSeries Specifications

Browse online or download Specifications for Water heaters & boilers Rheem S GSeries. Rheem S GSeries Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FORM NO. R11-861 REV. 1
Air
Package Gas Electric
RKNL-G Series
RKNL-G Series
With ClearControl
and VFD Technology
Nominal Sizes 7.5, 10 & 12.5 Tons [26.4, 35.2 & 44 kW]
ASHRAE 90.1-2010 Compliant
Rheem Commercial Classic
®
Series
Package Gas Electric Unit
featuring HumidiDry
Technology
Unit shown with optional
louvered coil protection.
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - Technology

FORM NO. R11-861 REV. 1AirPackage Gas ElectricRKNL-G SeriesRKNL-G SeriesWith ClearControl™and VFD TechnologyNominal Sizes 7.5, 10 & 12.5 Tons [26.

Page 2 - TABLE OF CONTENTS

AirUnit Features & BenefitsRKNL-G Series1043384241443940

Page 3

AirModel Number IdentificationRKNL-G Series11R K N L — G 090 C R 15 E X X XEconomizer Option (See Next Page)Factory Installed Options (See Next Page)I

Page 4

AirOptionsRKNL-G Series12Option Code Hail GuardStainless SteelHeat ExchangerNon-Powered ConvenienceOutlet/UnfusedService DisconnectLow Ambient/Comfort

Page 5

AirSelection Procedure RKNL-G Series13To select an RKNL-G Cooling and Heating unit to meet a jobrequirement, follow this procedure, with example, usin

Page 6

AirGeneral DataRKNL-G Series14NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- SeriesG090CR15E G090CR22E G090CS15E G

Page 7

AirGeneral DataRKNL-G Series15NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- Series G090CT15E G090CT22E G090DR15E

Page 8

AirGeneral DataRKNL-G Series16NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- Series G090DS15E G090DS22E G090DT15E

Page 9 - SYSTEM FEATURES

AirGeneral DataRKNL-G Series17NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- Series G120CR15E G120CR22E G120CS15E

Page 10 - RKNL-G Series

AirGeneral DataRKNL-G Series18NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- SeriesG120DR15E G120DR22E G120DS15E G

Page 11

AirGeneral DataRKNL-G Series19NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- Series G151CR15E G151CR25E G151CS15E

Page 12

AirTable of ContentsRKNL-G Series2TABLE OF CONTENTSUnit Features & Benefits ...

Page 13 - Selection Procedure

AirGeneral DataRKNL-G Series20NOM. SIZES 6-12.5 TONS [21.1-44.0 kW] ASHRAE 90.1-2007 COMPLIANT MODELSModel RKNL- Series G151DR15E G151DR25E G151DS15E

Page 14

AirGeneral Data NotesRKNL-G Series21NOTES:1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross ca

Page 15 - CONTINUED

AirGross Systems Performance DataRKNL-G Series22ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 3600 [

Page 16

AirGross Systems Performance DataRKNL-G Series23ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 4800 [

Page 17

AirGross Systems Performance DataRKNL-G Series24ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 6000 [

Page 18

AirGross Systems Performance DataRKNL-G SeriesENTERING INDOOR AIR @ 75°F [23.9°C] dbE ➀wbE 65.3°F [18.5°C] 64°F [17.8°C] 62.5°F [16.9°C]CFM [L/s] 1800

Page 19

AirIndoor Airflow PerformanceRKNL-G Series26ENTERING INDOOR AIR @ 75°F [23.9°C] dbE ➀wbE 65.3°F [18.5°C] 64°F [17.8°C] 62.5°F [16.9°C]CFM [L/s] 2400 [

Page 20

AirGross Systems Performance DataRKNL-G Series27ENTERING INDOOR AIR @ 75°F [23.9°C] dbE ➀wbE 65.3°F [18.5°C] 64°F [17.8°C] 62.5°F [16.9°C]CFM [L/s]300

Page 21

AirIndoor Airflow PerformanceRKNL-G Series28AIRFLOW PERFORMANCE—7.5 TON [26.4 kW] — 60 Hz — SIDEFLOWAirFlowCFM [L/s]Capacity 7.5 Tons [26.4 kW]Exter

Page 22

AirIndoor Airflow PerformanceRKNL-G Series29AirFlowCFM [L/s]Capacity 10 Tons [35.1 kW]External Static Pressure—Inches of Water [kPa]0.1 [.02] 0.2 [.

Page 23

AirUnit Features & BenefitsRKNL-G Series3• R-410A HFC refrigerant.• Complete factory charged, wired and run tested.• Scroll compressors with inter

Page 24

AirIndoor Airflow PerformanceRKNL-G Series30AIRFLOW PERFORMANCE—12.5 TON [44.0 kW] — SIDEFLOW] AirFlowCFM [L/s]Capacity 12.5 Tons [43.9 kW]Voltage 2

Page 25

AirElectrical DataRKNL-G Series31ELECTRICAL DATA – RKNL- SERIESG090CR G090CS G090CT G090DR G090DS G090DT G120CR G120CS G120DR G120DSUnit InformationUn

Page 26

AirElectrical DataRKNL-G Series32ELECTRICAL DATA – RKNL- SERIESG151CR G151CS G151DR G151DSUnit InformationUnit OperatingVoltage Range187-253 187-253 4

Page 27

33AirDimensional DataRKNL-G Series[ ] Designates Metric ConversionsBOTTOM VIEWIllustrationST-A0715-03-X1

Page 28 - AIRFLOW CORRECTION FACTORS

AirDimensional DataRKNL-G Series34SUPPLY AND RETURN DIMENSIONS FOR DOWNFLOW APPLICATIONSSUPPLY AND RETURN DIMENSIONS FOR HORIZONTAL APPLICATIONS*RECOM

Page 29 - 10 TON [35.2 kW]

AirDimensional DataRKNL-G Series35[ ] Designates Metric Conversions

Page 30 - IWC 12.5 TON [44.0 kW]

AirDimensional DataRKNL-G Series36[ ] Designates Metric ConversionsWEIGHTSAccessory Shipping—lbs [kg]Economizer 90 [40.82]Power Exhaust 44 [19.96]F

Page 31

AirAccessoriesRKNL-G Series37FIELD INSTALLED ACCESSORY EQUIPMENTAccessoryModelNumberInstalledWeightLbs. [kg]Thermostats See Thermostat Specification S

Page 32

AirAccessoriesRKNL-G Series38THERMOSTATS* Photos are representative. Actual models may vary.For detailed thermostat match-up information, see specific

Page 33 - BOTTOM VIEW

39AirAccessoriesRKNL-G SeriesROOM TEMPERATURE SENSOR RHC-ZNS1with TIMED OVERRIDE BUTTON10kΩ room temperature sensor transmits room temperature to DDC

Page 34 - ST-A0736-02-X1

AirUnit Features & BenefitsRKNL-G Series4Rheem Package equipment is designed from the ground up withthe latest features and benefits required to c

Page 35 - Dimensional Data

AirAccessoriesRKNL-G Series40BACnet®COMMUNICATION CARD RXRX-AY01The field installed BACnet®Communication Card allows the RTU-C unit controller to comm

Page 36 - ST-A0741-02

41AirAccessoriesRKNL-G Series Features Honeywell Controls Available Factory Installed or Field Accessory Gear Driven Direct Drive Actuator Fully Modul

Page 37 - Installed

AirAccessoriesRKNL-G Series42ECONOMIZER FOR HORIZONTAL DUCT INSTALLATIONField Installed OnlyAXRD-RJCM3—Single Enthalpy (Outdoor)RXRX-AV03—Dual Enthalp

Page 38 - THERMOSTATS

43AirAccessoriesRKNL-G SeriesNOTES: ➀ Power exhaust is factory set on high speed motor tap. [ ] Designates Metric Conversions➁ CFM is per fan at 0&

Page 39 - NETWORKED DDC APPLICATIONS

AirAccessoriesRKNL-G Series44FRESH AIR DAMPERMOTORIZED DAMPER KITRXRX-AW02(Motor Kit for AXRF-KDA1)IllustrationST-A0886-387951-17aAXRF-KDA1 (Manual)DO

Page 40 - Field Installed

45AirAccessoriesRKNL-G SeriesFRESH AIR DAMPER (Cont.)AXRF-JDA1 (Manual)AXRF-JDB1 (Motorized)IllustrationADS-7937-58IllustrationST-A0901-01HORIZONTAL A

Page 41 - ADS-7949-11

AirAccessoriesRKNL-G Series46ROOFCURBS (Full Perimeter) Rheem’s roofcurb design can be utilized on all 6-12.5 ton[21.1-44.0 kW] RKNL- models. Two avai

Page 42 - Field Installed Only

47AirAccessoriesRKNL-G SeriesROOFCURB ADAPTERS(-)PDC-075(-)PDC-100/101RXPK-C12RXRX-CGCC12NEW MODELS(All Share Common Cabinet)RKNL- G090, G120, G151OLD

Page 43 - AXRD-RJCM3 ECONOMIZERS

AirAccessoriesRKNL-G Series48ROOFCURB ADAPTERS (Cont.)RXRX-CDCE50IllustrationADS-7952-02Sheet 2IllustrationADS-7952-02Sheet 1[ ] Designates Metric

Page 44 - FRESH AIR DAMPER

49AirAccessoriesRKNL-G SeriesROOFCURB ADAPTERS (Cont.)RXRX-CFCE54IllustrationADS-7952-01Sheet 1IllustrationADS-7952-01Sheet 2[ ] Designates Metric

Page 45 - FRESH AIR DAMPER (Cont.)

AirUnit Features & BenefitsRKNL-G Series5Inside the control box ( ), each electri-cal component is clearly identified with a label that matches th

Page 46 - ROOFCURBS (Full Perimeter)

AirAccessoriesRKNL-G Series50ROOFCURB ADAPTERS (Cont.)RXRX-CFCE56IllustrationADS-7952-03Sheet 2IllustrationADS-7952-03Sheet 1[ ] Designates Metric

Page 47 - ROOFCURB ADAPTERS

51AirAccessoriesRKNL-G SeriesROOFCURB ADAPTERS (Cont.)RXRX-CGCC12IllustrationADS-7952-04Sheet 1IllustrationADS-7952-04Sheet 2[ ] Designates Metric

Page 48 - ROOFCURB ADAPTERS (Cont.)

AirAccessoriesRKNL-G Series52IllustrationST-A0881-02[ ] Designates Metric ConversionsCONCENTRIC DIFFUSER APPLICATIONIllustrationST-A0840-02DOWNFLOW

Page 49

53AirAccessoriesRKNL-G Series[ ] Designates Metric ConversionsIllustrationST-A0881-03DOWNFLOW TRANSITION DRAWINGSRXMC-CF06 Used with RXRN-AA66or RX

Page 50

AirAccessoriesRKNL-G Series54DOWNFLOW TRANSITION DRAWINGSRXMC-CD04 Used with RXRN-FA65or RXRN-FA75Concentric Diffusers.795103IllustrationADS-7951-03[

Page 51

55AirAccessoriesRKNL-G SeriesModel No.Flow RateCFM [L/s]Static Pressurein. w.c. [kPa]Throw ➁➂Feet [m]Neck Velocityfpm [m/s]Noise Level ➃(dbA)RXRN-FA65

Page 52 - DOWNFLOW TRANSITION DRAWINGS

AirAccessoriesRKNL-G Series56ENGINEERING DATA➀CONCENTRIC DIFFUSER—STEP DOWN18" x 28" [457.2 x 711.2 mm]RXRN-AA61 (8.5 & 10 Ton [29.9 kW

Page 53

57AirAccessoriesRKNL-G SeriesENGINEERING DATA➀CONCENTRIC DIFFUSER—STEP DOWN18" x 32" [457.2 x 813 mm]RXRN-AA66 (12.5 & 15 Ton [44.0 &

Page 54

AirAccessoriesRKNL-G Series58FLUSH MOUNT CONCENTRIC DIFFUSER—FLUSHRXRN-FA75 (7.5 & 8.5 Ton [26.4 & 29.9 kW] Models)ENGINEERING DATA➀Model No.F

Page 55 - CONCENTRIC DIFFUSER—STEP DOWN

59AirAccessoriesRKNL-G SeriesCONCENTRIC DIFFUSER—FLUSHand 18" x 28" [457.2 x 711.2 mm]RXRN-AA71 (8.5 & 10 Ton [29.9 & 35.2] Models)F

Page 56

AirUnit Features & BenefitsRKNL-G Series6Factory installed VFD (variable fre-quency drive) supply fan optimizesenergy usage year round by providin

Page 57

AirAccessoriesRKNL-G Series60ENGINEERING DATA➀Model No.Flow RateCFM [L/s]Static Pressurein w.c. [kPa]Throw ➁➂Feet [m]Neck Velocityfpm [m/s]Noise Level

Page 58

61AirMechanical SpecificationsRKNL-G SeriesGuide Specifications RKNL-G090 & G120You may copy this document directly into your building specificati

Page 59 - CONCENTRIC DIFFUSER—FLUSH

AirMechanical SpecificationsRKNL-G Series6223 09 23.13.B. Open protocol, direct digital controller:1. Shall be ASHRAE 62-2001 compliant.2. Shall accep

Page 60

63AirMechanical SpecificationsRKNL-G Series23 09 33 Sequence of Operations for HVAC Controls23 09 93.13 Decentralized, Rooftop Units:23 09 93.13 INSER

Page 61 - GAS HEAT PACKAGED ROOFTOP

AirMechanical SpecificationsRKNL-G Series6423 81 19.13.H. Unit Cabinet1. Unit cabinet shall be constructed of galvanized steel.2. Unit cabinet exterio

Page 62 - Mechanical Specifications

65AirMechanical SpecificationsRKNL-G Series4. Optional Stainless Steel Heat Exchanger constructiona. Use energy saving, direct-spark ignition system.

Page 63

AirMechanical SpecificationsRKNL-G Series6623 81 19.13.N. Condenser Fans and Motors1. Condenser fan motors:a. Shall be a totally enclosed motor.b. Sha

Page 64

AirMechanical SpecificationsRKNL-G Series677. Convenience Outlet:a. Non-Powered convenience outlet.b. Outlet shall be powered from a separate 115-120v

Page 65

AirWiring DiagramsRKNL-G Series68

Page 66

69AirWiring DiagramsRKNL-G Series

Page 67

AirUnit Features & BenefitsRKNL-G Series7Also inside the blower compart-ment is the low-ambient control( ), low-pressure switch ( ), high-pressure

Page 68 - Wiring Diagrams

AirLimited WarrantyRKNL-G Series70GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal

Page 69

71AirNotesRKNL-G Series

Page 70 - YOUR RETAILER

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Page 71

AirUnit Features & BenefitsRKNL-G Series8The compressorcompartmenthouses the heart-beat of the unit. Thescroll compressor( ) is known for itslong

Page 72 - The new degree of comfort

AirUnit Features & BenefitsRKNL-G Series9HUMIDIDRY™SYSTEM FEATURESHumidiDry™ is Rheem’s exclusive dehumidification packageunit solution. It delive

Comments to this Manuals

No comments