24
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 6000 [2832] 4250 [2006] 4000 [1888] 6000 [2832] 4250 [2006] 4000 [1888] 6000 [2832] 4250 [2006] 4000 [1888]
DR
.14 .08 .07 .14 .08 .07 .14 .08 .07
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
190.2 [55.7]
115 [33.7]
9.5
177 [51.9]
96.5 [28.3]
9.1
175.1 [51.3]
93.8 [27.5]
9.1
179.1 [52.5]
136.8 [40.1]
9.3
166.6 [48.8]
114.7 [33.6]
9.0
164.8 [48.3]
111.6 [32.7]
9.0
170.2 [49.9]
157.1 [46.0]
9.2
158.3 [46.4]
131.8 [38.6]
8.9
156.6 [45.9]
128.1 [37.6]
8.8
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
184.9 [54.2]
112.8 [33.1]
10.0
172 [50.4]
94.7 [27.7]
9.6
170.2 [49.9]
92.1 [27.0]
9.6
173.7 [50.9]
134.6 [39.4]
9.8
161.6 [47.4]
112.9 [33.1]
9.5
159.9 [46.9]
109.8 [32.2]
9.4
164.8 [48.3]
154.9 [45.4]
9.7
153.3 [44.9]
129.9 [38.1]
9.4
151.7 [44.5]
126.4 [37.0]
9.3
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
179.6 [52.6]
110.5 [32.4]
10.5
167.1 [49]
92.7 [27.2]
10.1
165.3 [48.4]
90.2 [26.4]
10.1
168.5 [49.4]
132.3 [38.8]
10.4
156.8 [45.9]
111 [32.5]
10.0
155.1 [45.4]
107.9 [31.6]
10.0
159.6 [46.8]
152.6 [44.7]
10.2
148.5 [43.5]
128 [37.5]
9.9
146.9 [43.0]
124.5 [36.5]
9.8
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
174.5 [51.1]
108.1 [31.7]
11.1
162.3 [47.6]
90.7 [26.6]
10.7
160.6 [47.1]
88.2 [25.8]
10.6
163.4 [47.9]
129.9 [38.1]
10.9
152 [44.5]
108.9 [31.9]
10.6
150.4 [44.1]
106 [31.1]
10.5
154.4 [45.3]
150.2 [44.0]
10.8
143.7 [42.1]
126 [36.9]
10.4
142.2 [41.7]
122.5 [35.9]
10.4
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
169.5 [49.7]
105.6 [30.9]
11.7
157.7 [46.2]
88.5 [25.9]
11.3
156 [45.7]
86.1 [25.2]
11.2
158.3 [46.4]
127.3 [37.3]
11.6
147.3 [43.2]
106.8 [31.3]
11.2
145.7 [42.7]
103.9 [30.4]
11.1
149.4 [43.8]
147.6 [43.3]
11.4
139 [40.7]
123.8 [36.3]
11
137.5 [40.3]
120.4 [35.3]
11
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
164.5 [48.2]
102.9 [30.1]
12.3
153.1 [44.9]
86.3 [25.3]
11.9
151.4 [44.4]
83.9 [24.6]
11.8
153.4 [45.0]
124.6 [36.5]
12.2
142.7 [41.8]
104.5 [30.6]
11.8
141.2 [41.4]
101.7 [29.8]
11.7
144.5 [42.3]
144.5 [42.3]
12.1
134.4 [39.4]
121.6 [35.6]
11.6
133 [39.0]
118.2 [34.6]
11.6
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
159.7 [46.8]
100.1 [29.3]
13.0
148.6 [43.5]
83.9 [24.6]
12.6
147 [43.1]
81.6 [23.9]
12.5
148.6 [43.5]
121.8 [35.7]
12.9
138.2 [40.5]
102.2 [29.9]
12.4
136.8 [40.1]
99.4 [29.1]
12.4
139.7 [40.9]
139.7 [40.9]
12.7
130 [38.1]
119.2 [34.9]
12.3
128.6 [37.7]
115.9 [34.0]
12.2
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
155 [45.4]
97.1 [28.5]
13.7
144.2 [42.3]
81.5 [23.9]
13.2
142.7 [41.8]
79.2 [23.2]
13.2
143.9 [42.2]
118.9 [34.8]
13.6
133.9 [39.2]
99.7 [29.2]
13.1
132.4 [38.8]
97 [28.4]
13.0
135 [39.6]
135 [39.6]
13.5
125.6 [36.8]
116.7 [34.2]
13
124.2 [36.4]
113.5 [33.3]
12.9
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
150.4 [44.1]
94 [27.6]
14.5
139.9 [41.0]
78.9 [23.1]
14.0
138.4 [40.6]
76.7 [22.5]
13.9
139.3 [40.8]
115.8 [33.9]
14.3
129.6 [38]
97.2 [28.5]
13.8
128.2 [37.6]
94.5 [27.7]
13.8
130.4 [38.2]
130.4 [38.2]
14.2
121.3 [35.5]
114.2 [33.5]
13.7
120 [35.2]
111 [32.5]
13.6
120
[48.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
145.9 [42.8]
90.8 [26.6]
15.2
135.8 [39.8]
76.2 [22.3]
14.7
134.3 [39.4]
74.1 [21.7]
14.6
134.8 [39.5]
112.6 [33.0]
15.1
125.4 [36.8]
94.5 [27.7]
14.6
124.1 [36.4]
91.9 [26.9]
14.5
125.9 [36.9]
125.9 [36.9]
15.0
117.1 [34.3]
111.5 [32.7]
14.5
115.9 [34.0]
108.4 [31.8]
14.4
125
[51.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
141.5 [41.5]
87.5 [25.6]
16.1
131.7 [38.6]
73.4 [21.5]
15.5
130.3 [38.2]
71.4 [20.9]
15.4
130.4 [38.2]
109.3 [32.0]
15.9
121.3 [35.6]
91.7 [26.9]
15.4
120 [35.2]
89.2 [26.1]
15.3
121.5 [35.6]
121.5 [35.6]
15.8
113 [33.1]
108.7 [31.9]
15.2
111.8 [32.8]
105.7 [31.0]
15.2
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power —KW input
NOTES: When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
[ ] Designates Metric Conversions
GROSS SYSTEMS PERFORMANCE DATA—G151