Rheem Classic Series: Single Stage Specifications Sheet

Browse online or download Specifications Sheet for Heat pumps Rheem Classic Series: Single Stage. Rheem Classic Series: Single Stage Specification Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
16.0
Rheem Classic
®
Series
Heat Pumps
FORM NO. P11-801 REV. 1
RPNL- Series
Efficiencies up to14.50 SEER/12.00 EER/9.50 HSPF
Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kW]
Attractive, louvered wrap around jacket protects coil from
weather extremes and yard hazards. Top grille is steel rein-
forced for extra strength. Cabinet is powder painted for all
weather protection.
Four sided outdoor coil design allows compressor operation
with access panel removed.
Air is discharged upward away from bushes and shrubs. The
discharge pattern of the top grille provides minimum air
restriction, resulting in quiet fan operation.
Combination Grille/Motor Mount secures the fan motor to the
underside of the discharge grille.
All controls are accessible by removing one service panel.
Removable top grille provides access to the outdoor fan motor
and outdoor coil.
Compressor compartment offers additional protection from
the elements and reduces operating noise.
Single speed, 8-pole fan motor is designed for quieter, energy-
saving operation.
Non-cycling reversing valve and demand defrost.
All models meet or exceed a 1000-hour salt spray test per
ASTM B117 Standard Practice for Operating Salt Spray Test-
ing Apparatus.
Air
Heat Pumps
RPNL Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Contractor for details or visit
www.energystar.gov.”
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Heat Pumps

16.0Rheem Classic®SeriesHeat PumpsFORM NO. P11-801 REV. 1RPNL- SeriesEfficiencies up to14.50 SEER/12.00 EER/9.50 HSPFNominal Sizes 2 to 5 Ton [7.03 to

Page 2 - TABLE OF CONTENTS

AirPerformance DataRPNL Series10Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Page 3 - Model Features

AirPerformance DataRPNL Series11Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Page 4 - 200-Series *

AirPerformance DataRPNL Series12Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Page 5

AirPerformance DataRPNL Series13Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Page 6

AirPerformance DataRPNL Series14Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB I

Page 7

AirElectrical & Physical DataRPNL Series15ModelNumberRPNL-ELECTRICAL PHYSICALPhaseFrequency (Hz)Voltage (Volts)CompressorFan MotorFull LoadAmperes

Page 8

AirUnit DimensionsRPNL Series16AIR DISCHARGEALLOW 60⬙ [1524 mm] CLEARANCEAIR INLETS(LOUVERS)ALLOW 6⬙ [152 mm]MIN. CLEARANCE3 SIDESALLOW 24⬙ [610 mm]AC

Page 9

AirRefrigerant Line Size InformationRPNL Series17SystemCapacityLine SizeConnectionSize(Inch I.D.)[mm]Liquid Line Sizing (R-410A)Outdoor Unit Above or

Page 10 - 5/17/2012

AirLimited WarrantyRPNL Series18GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Page 11

AirNotesRPNL Series19

Page 12

AirTable of ContentsRPNL Series2TABLE OF CONTENTSModel Features ...

Page 13

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Page 14

AirModel FeaturesRPNL Series3All controls and compressor are accessiblefor servicing by removal of the service panel.Drawn Painted Base Pan.Model Feat

Page 15 - Electrical and Physical Data

AirModel I.D./Accessories/CompressorRPNL Series4Model Number IdentificationR P N L 024 J AZRHEEM REMOTEHEAT PUMPN = 13 SEER DESIGNSERIESL = R-410ACOOL

Page 16 - Unit Dimensions

AirPerformance DataRPNL Series5Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB In

Page 17 - RPNL Series

AirPerformance DataRPNL Series6Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB In

Page 18

AirPerformance DataRPNL Series7Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB In

Page 19

AirPerformance DataRPNL Series8Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB In

Page 20 - The new degree of comfort

AirPerformance DataRPNL Series9Model NumbersAHRI Cooling Performance AHRI Heating Performance (70°F [21°C] Indoor)80°F [26.5°C] DB/67°F [19.5°C] WB In

Comments to this Manuals