Rheem Classic Heat Pump Pool Heaters Installation Manual

Browse online or download Installation Manual for Above ground pool accessories Rheem Classic Heat Pump Pool Heaters. Rheem Classic Heat Pump Pool Heaters Installation and Operation Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION & OPERATING
INSTRUCTIONS
Catalog No. RM6000.552E Effective: 06-28-13 Replaces: 11-23-10 P/N 241380 Rev. 6
92-103778-01-06
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids or other combustible materials in the vicinity of this or any other appliance. To
do so may result in an explosion or fire.
Model Series
5350, 6350,
6350HC, 8350 &
8350HC
Heat Pump
Pool & Spa
Heater
USC
L
I
S
T
E
D
R
NOTE: The instructions in this manual are for the use of qualified individuals specially trained and experienced
in the installation and maintenance of this type of equipment and related system components. Installation and
service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install,
service, or maintain this equipment.
This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a
safe place for future use.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Pool & Spa

INSTALLATION & OPERATINGINSTRUCTIONSCatalog No. RM6000.552E Effective: 06-28-13 Replaces: 11-23-10 P/N 241380 Rev. 6 92-103778-01-06FOR Y

Page 2 - Deletions: None

Controls & Indicator Lamps(Analog Models)Your analog heat pump pool heater incorporates safe-ty controls and indicators to ensure its safe,

Page 3 - Water Chemistry

• Compressor Delay Active (amber lamp): Undernormal operation, when lit, indicates compressoranti-short cycle timer is active. The fan will run

Page 4 - CONTENTS

Digital Controls OperatingInstructionsThe electronic board has the capability of memorizingtwo different programmed temperature settings as fol-lows (

Page 5 - Pay Attention to These Terms

System Start-Up1. Verify that the Digital Board is displaying a temper-ature and the pool pump is running and water iscirculating properly.2

Page 6 - Installation Considerations

14TroubleshootingIf your unit does not operate, or simply does not heatyour pool water, Fault Codes (digital models), or theindicator lamps

Page 7 - Electrical Connections

15• Is airflow through the unit being obstructed?Restrictions such as shrubbery, tall grass, dirtycoils, or any other obstruction to airfl

Page 8

Fault Code Meaning of CodeOFF The desired programmed temperature point is lower than 60°F (15°C).LP & LP3Shortage of refrigerant gas in the unit o

Page 9 - Pressure Drop

Plumbing DiagramsWATER IN(FROM POOL ORSPA)FILTERCHECKVALVECHEMICALINTRODUCTIONWATER OUT(TO POOL ORSPA)Fig. 6: For systems with pumps of less than 2 HP

Page 10 - (Analog Models)

18WATER IN(FROM POOL ORSPA)FILTERCHECKVALVECHEMICALINTRODUCTIONWATER OUT(TO POOL ORSPA)Fig. 7: For systems with pumps of 2 HP or greater (over 80 gpm)

Page 11 - Controls (Digital Models)

19Fig. 8: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater

Page 12 - 6350HC and 8350HC Only)

2Rev. 6 reflects the following:Changes to: Installation Considerations on pages 6-7, High Wind Installation diagram on page 8, Table C on page 16,Wi

Page 13 - Freeze Protection

20Fig. 9: Pool Piping for Heat Pump Pool Heaters, Multiple, Primary/SecondaryUNITSUNITSUNITS

Page 14 - Maintenance

21Wiring Diagram — 208V/230V Single-Phase — Analog Models

Page 15 - Service Call Verification

Wiring Diagram 208V/230V Single-Phase Digital Models22

Page 16

Wiring Diagram 208V/230VThree-Phase Analog Models23

Page 17 - Plumbing Diagrams

24Wiring Diagram 208V/230V Three-Phase Digital Models

Page 18

25Wiring Diagram460V Three-PhaseAnalog Models

Page 19

26Installing a Remote ControlDevice on Analog HeatersWiringFor a 2-wire control, use the TOTAL and COMMONconnections on the heat pump poo

Page 21

Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468Heat Pump Service 1-800-260-2758Litho in U.S.A.28

Page 22

3Water Chemistry(Corrosive water voids all warranties)For your health and the protection of your pool equipment, it is essential that your water be ch

Page 23 - Three-Phase Analog Models

4Water Chemistry 3Warnings 5Pay Attention to These Terms 5Introduction 6Installation Considerations 6Electrical Connections 7Water Connections 9Press

Page 24

CAUTION: Improper chemical content in a swim-ming pool or spa can damage the heat pump poolheater. DO NOT add pool chemicals to the skim

Page 25 - Analog Models

IntroductionThis manual contains important information on theuse, maintenance and troubleshooting of your newheat pump pool heater. Th

Page 26 - Device on Digital Heaters

7GASHEATERAIRFLOWINAIRFLOWINAIR FLOW OUT3 FTMIN12”MIN60”MINFig. 1: Installation Clearances• Irrigation water should be directed away from theheat pum

Page 27

8PAD SPECIFICATION:GREATER THAN OR EQUAL TO 4” THICK SOLID CONCRETE 3000 P. S. I. OR GREATER LOAD RATINGPAD LENGTH GREATER THAN OR EQUAL TO UNIT LENGT

Page 28 - Litho in U.S.A

Water Connections1. Connect the heat pump pool heater in the returnwater line between the filter and the pool/spa. Seethe Plumbing Diagrams beginni

Comments to this Manuals