INSTALLATION & OPERATINGINSTRUCTIONSCatalog No. RM6000.552E Effective: 06-28-13 Replaces: 11-23-10 P/N 241380 Rev. 6 92-103778-01-06FOR Y
Controls & Indicator Lamps(Analog Models)Your analog heat pump pool heater incorporates safe-ty controls and indicators to ensure its safe,
• Compressor Delay Active (amber lamp): Undernormal operation, when lit, indicates compressoranti-short cycle timer is active. The fan will run
Digital Controls OperatingInstructionsThe electronic board has the capability of memorizingtwo different programmed temperature settings as fol-lows (
System Start-Up1. Verify that the Digital Board is displaying a temper-ature and the pool pump is running and water iscirculating properly.2
14TroubleshootingIf your unit does not operate, or simply does not heatyour pool water, Fault Codes (digital models), or theindicator lamps
15• Is airflow through the unit being obstructed?Restrictions such as shrubbery, tall grass, dirtycoils, or any other obstruction to airfl
Fault Code Meaning of CodeOFF The desired programmed temperature point is lower than 60°F (15°C).LP & LP3Shortage of refrigerant gas in the unit o
Plumbing DiagramsWATER IN(FROM POOL ORSPA)FILTERCHECKVALVECHEMICALINTRODUCTIONWATER OUT(TO POOL ORSPA)Fig. 6: For systems with pumps of less than 2 HP
18WATER IN(FROM POOL ORSPA)FILTERCHECKVALVECHEMICALINTRODUCTIONWATER OUT(TO POOL ORSPA)Fig. 7: For systems with pumps of 2 HP or greater (over 80 gpm)
19Fig. 8: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater
2Rev. 6 reflects the following:Changes to: Installation Considerations on pages 6-7, High Wind Installation diagram on page 8, Table C on page 16,Wi
20Fig. 9: Pool Piping for Heat Pump Pool Heaters, Multiple, Primary/SecondaryUNITSUNITSUNITS
21Wiring Diagram — 208V/230V Single-Phase — Analog Models
Wiring Diagram 208V/230V Single-Phase Digital Models22
Wiring Diagram 208V/230VThree-Phase Analog Models23
24Wiring Diagram 208V/230V Three-Phase Digital Models
25Wiring Diagram460V Three-PhaseAnalog Models
26Installing a Remote ControlDevice on Analog HeatersWiringFor a 2-wire control, use the TOTAL and COMMONconnections on the heat pump poo
27
Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468Heat Pump Service 1-800-260-2758Litho in U.S.A.28
3Water Chemistry(Corrosive water voids all warranties)For your health and the protection of your pool equipment, it is essential that your water be ch
4Water Chemistry 3Warnings 5Pay Attention to These Terms 5Introduction 6Installation Considerations 6Electrical Connections 7Water Connections 9Press
CAUTION: Improper chemical content in a swim-ming pool or spa can damage the heat pump poolheater. DO NOT add pool chemicals to the skim
IntroductionThis manual contains important information on theuse, maintenance and troubleshooting of your newheat pump pool heater. Th
7GASHEATERAIRFLOWINAIRFLOWINAIR FLOW OUT3 FTMIN12”MIN60”MINFig. 1: Installation Clearances• Irrigation water should be directed away from theheat pum
8PAD SPECIFICATION:GREATER THAN OR EQUAL TO 4” THICK SOLID CONCRETE 3000 P. S. I. OR GREATER LOAD RATINGPAD LENGTH GREATER THAN OR EQUAL TO UNIT LENGT
Water Connections1. Connect the heat pump pool heater in the returnwater line between the filter and the pool/spa. Seethe Plumbing Diagrams beginni