INSTALLATION
28
TYPICAL INSTALLATION OUTDOOR LOCATION
Gas Details
Hourly Gas
Consumption
(MJ)
Min. Gas
Pressure
(kPa)
Test Point Gas
Pressure
(kPa)
Max. Gas
Pressure
(kPa)
090
135
170
090 to 170
090
135
170
090 to 170
Natural
30
35
40
1.13
1.00
1.00
1.00
3.50
Propane
30
35
40
2.75
2.70
2.70
2.70
3.50
Butane
30
30
30
2.75
2.70
2.70
2.70
3.50
Town / TLP
27/25
32/30
38/35
0.75
0.45
0.40
0.35
3.50
Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N,
P, B or T is included in the model number, e.g. 311135N0, to denote gas type.
Technical data is subject to change.
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 43 44