Rheem GT-199PV User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
COMMERCIAL TANKLESS SERIES
M
AXIMUM HOT WATER FLOW RATE AND TEMPERATURE RISE
Temp. Rise (°F) 35 45 50 60 70 77 90 100 110 120 130 140
Water Flow (GPM) 8.5 7.4 6.6 5.5 4.7 4.3 3.7 3.3 3.0 2.8 2.6 2.4
C
LEARANCE TO
COMBUSTIBLES
(
inches)
M
ODEL
N
UMBER SIDE REAR
GT-199PV 1/2 0 12
GT-199X 1/2 0 12
GT-199DV 1/2 0 12
Minimum flow rate required to initiate heating cycle .66 gpm.
A
bove estimates are for sizing purposes only.
FRONT
TOP &
BOTTOM
RHEEM-RUUD GT-199 MANIFOLD INSTALLATIONS
TEMP.
FLOW RATE (GPM)
RISE (°F) 1 UNIT 2 UNITS 5 UNITS 10 UNITS 15 UNITS 20 UNITS
140 2.4 4.7 11.9 23.7 35.6 47.4
130 2.6 5.1 12.8 25.5 38.3 51.1
120 2.8 5.5 13.8 27.7 41.5 55.3
110 3.0 6.0 15.1 30.2 45.3 60.3
100 3.3 6.6 16.6 33.2 49.8 66.4
90 3.7 7.4 18.4 36.9 55.3 73.7
80 4.1 8.3 20.7 41.5 62.2 83.0
77 4.3 8.6 21.5 43.1 64.6 86.2
70 4.7 9.5 23.7 47.4 71.1 94.8
60 5.5 11.1 27.7 55.3 83.0 110.6
50 6.6 13.3 33.2 66.4 99.6 132.7
45 7.4 14.7 36.9 73.7 110.6 147.5
35 8.5 17.0 42.5 85.0 127.5 170.0
W
ater Heater Flow Rate Curves
0
1
2
3
4
5
6
7
8
9
10 15 20 25 30 35 40 45 50 55 60 70 80 90 100 120 140
Delta-T
GPM
Max Flow
Page view 2
1 2 3 4

Comments to this Manuals