Rheem Classic
®
Series
Heat Pump
FORM NO. P11-806 REV. 2
RP14 Series
Efficiencies: 14 SEER/11.5 EER 8.2 HSPF
Nominal Sizes 1
1
/2 to 5 Ton [5.28 to 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
New composite base pan – dampens sound, captures louver
panels, eliminates corrosion and reduces number of fasteners
needed
Improved tubing design – reduces vibration and stress, mak-
ing unit quieter and reducing opportunity for leaks
Optimized defrost characteristics - decrease defrosting and
provide better home comfort
Powder coat paint system – for a long lasting professional finish
Optimized reversing valve sizing – improves shifting perfor-
mance for quieter unit operation and increased life of the
system
Enhanced mufflers – help to dissipate vibration energy for
quieter unit operation
Scroll compressor – a sound abating feature added to the
compressor significantly reduces noise when system transi-
tions in and out of defrost mode
Modern cabinet aesthetics – increased curb appeal with visu-
ally appealing design
Curved louver panels – provide ultimate coil protection,
enhance cabinet strength, and increased cabinet rigidity
Optimized fan orifice – optimizes airflow and reduces unit
sound
Rust resistant screws – confirmed through 1500-hour salt
spray testing
PlusOne™ Expanded Valve Space – 3"-4"-5" service valve
space – provides a minimum working area of 27-square
inches for easier access
Integrated heat pump lift receptacle – allows standard CPVC
stands to be inserted into the base
PlusOne™ Triple Service Access – 15" wide, industry lead-
ing corner service access – makes repairs easier and faster.
The two fastener removable corner allows optimal access to
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier
cabinet reassembly
Diagnostic service window with two-fastener opening –
provides access to the TXV valves and the heat pump revers-
ing valve before opening the unit.
External gauge port access – allows easy connection of
“low-loss” gauge ports
Single-row condenser coil – makes unit lighter and allows thor-
ough coil cleaning to maintain “out of the box” performance
35% fewer cabinet fasteners and fastener-free base – allow
for faster access to internal components and hassle-free
panel removal
Service trays – hold fasteners or caps during service calls
QR code – provides technical information on demand for
faster service calls
Fan motor harness with extra-long wires – allows unit top to
be removed without disconnecting fan wire
Air
Heat Pumps
RP14 Series
“Proper sizing and installation of equipment is critical to achieve
optimal performance. Ask your Dealer for details or visit
www.energystar.gov.”
16.0
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Heat Pump

Rheem Classic®SeriesHeat PumpFORM NO. P11-806 REV. 2RP14 SeriesEfficiencies: 14 SEER/11.5 EER 8.2 HSPFNominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW]Coo

Page 2 - TABLE OF CONTENTS

Unit DimensionsMODELNUMBEROPERATING SHIPPINGH (Height) L (Length) W (Width) H (Height) L (Length) W (Width)INCHES mm INCHES mm INCHES mm INCHES mm INC

Page 3 - Available SKU

6⬙ (152.4)24⬙ (609.6)Service12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Service24⬙ (609.6)24⬙ recommended12⬙ minimum12⬙ (304.8)12⬙ (304.8)6⬙ (152.4)24⬙ (609.6)Ser

Page 4 - Features & Benefits

AirWiring Diagram/Application GuidelinesRP14 Series12FIGURE 4CONTROL WIRING FOR AIR HANDLERNOTES:1. Jumper “E” to “W2” totransfer control ofsupplement

Page 5

AirRefrigerant Line Size InformationRA14 Series13R-410A SystemCapacity ModelLiquid Line SizeConnection Size(Inch I.D.) [mm]Liquid Line Size(Inch O.D.)

Page 6 - Heat Pumps

AirRefrigerant Line Size InformationRA14 Series14R-410A SystemCapacity ModelVapor LineConnection Size(Inch I.D.) [mm]Vapor Line Size(Inch O.D.) [mm]Va

Page 7 - Air Handlers (For Reference)

AirPerformance DataRP14 Series15High Sales Volume Tested Combination (HSVTC)OutdoorUnitAir HandlerTotal CapacityBTU/H [kW]Net SensibleBTU/H [kW]Net La

Page 8 - Electrical Data

AirPerformance DataRP14 Series16RGPE: Two-Stage, Variable Speed 80% (upflow/horizontal) furnace with Comfort Control System RatingsOutdoorUnitFurnace

Page 9 - Thermostats

17AirPerformance DataRP14 Series17RGJF: 90 Plus Communicating Modulating Horizontal Gas Furnace equipped with Comfort Control, ECM RatingsOutdoorUnitF

Page 10 - Unit Dimensions

18AirPerformance DataRP14 SeriesAir Handler RatingsOutdoorUnitAir HandlerTotal CapacityBTU/H [kW]Net SensibleBTU/H [kW]Net LatentBTU/H [kW]SEER EERInd

Page 11 - CLEARANCES

AirGuide SpecificationsRP14 Series19GUIDE SPECIFICATIONS GeneralSystem DescriptionOutdoor-mounted, air-cooled, split-system heat pump unit suit-able f

Page 12 - Control Wiring

AirTable of ContentsRP14 Series2TABLE OF CONTENTSStandard Feature Table ...

Page 13

AirLimited WarrantyRP14 Series20GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Page 14

AirNotesRA14 Series21

Page 15 - RP14 Series

AirNotesRA14 Series22

Page 16

23AirNotesRA14 Series

Page 17

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Page 18

AirStandard Feature Table/Available SKUsRP14 Series3Feature 18 24 30 36 42 48 60R-410a Refrigerant √ √ √ √ √ √ √Maximum SEER 14 14 14 14 14 14 14Maxim

Page 19 - GUIDE SPECIFICATIONS

AirFeatures & BenefitsRP14 Series4The RP14 is our 14 SEER heat pump and is part of the Rheemheat pump product line that extends from 14 to 20 SEER

Page 20

AirFeatures & BenefitsRP14 Series5The entire cabinet has powder post paint ( ) achieving 1000hour salt spray rating, allowing the cabinet to retai

Page 21 - RA14 Series

AirModel Number IdentificationRP14 Series6RP 14 24 AJ1 N A *Brand ProductCategorySEER CapacityBTU/HRMajor Series* Voltage Type Controls MinorSeries**O

Page 22

R96 V A702 3 17 M S ABrand Series Motor Major Rev InputBTU/HR [kW]Stages Air Flow CabinetWidthConfiguration Nox Minor RevRheem 90 - 90 AFUE92 - 92 AFU

Page 23

Physical DataModel No.# RP1418 RP1424 RP1430 RP1436 RP1442 RP1448 RP1460Nominal Tonnage 1.5 2.0 2.5 3.0 3.5 4.0 5.0Valve ConnectionsLiquid Line O.D. –

Page 24 - The new degree of comfort

Accessories Model No. RP1418 RP1424 RP1430 RP1436 RP1442 RP1448 RP1460Compressor crankcase heater 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-1

Comments to this Manuals

No comments