INSTALLATION – SOLAR STORAGE TANK
23
REDUCING HEAT LOSSES
The cold water line to and the tempered water and hot water lines from the water heater must be
insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof
and UV resistant if exposed.
The pipe work between the solar storage tank and the solar collectors must be insulated in accordance
with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if
exposed. The insulation must be fitted up to the connections on both the solar storage tank and the
solar collectors.
ANODE TYPES
The correct anode type for the water supply being used must be fitted in the water heater (refer to
“Water Supplies” on page 52). The black anode is fitted as standard.
Total Dissolved Solids in water supply to the water heater Anode colour code
0 – 40 mg/L Green
40 – 600 mg/L Black
600 – 2500 mg/L Blue
SADDLING - PIPE WORK
To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket, we
recommend the use of self-drilling screws with a maximum length of 12 mm. Should pre drilling be
required, extreme caution must be observed when penetrating the jacket of the water heater.
Note: Damage to the cylinder as a result of saddling to the jacket will void the warranty.