Installation Checklist
11
A. Water Heater Location
Close to area of heated water demand.
Indoors and protected from moisture,
wet conditions and freezing
temperatures.
Area free of flammable vapors.
1,000 cu. ft unconditioned indoor space.
Provisions made to protect area from
water damage.
Sufficient room to service heater.
Eight inches (8") of clearance from
ceiling to top of heat pump water heater
to allow for air circulation.
Access to condensate disposal.
B. Water Supply
Water heater completely filled with
water.
Air purged from water heater and piping.
Water connections tight and free of
leaks.
C. Relief Valve
Temperature and Pressure Relief Valve
properly installed and discharge line run
to open drain.
Discharge line protected from freezing.
D. Wiring
Power Supply voltage agrees with water
heater rating plate.
Branch circuit wire and fusing or circuit
breaker of proper size. (Minimum 30
amp breaker)
Electrical connections tight and unit
properly grounded.
10 gauge wire.
E. Condensate Lines
Condensate lines from heat pump
installed correctly.
Condensate lines from heat pump run to
a suitable drain location.