Air
Model Features
RASL- JEC Series
3
The Rheem exclusive Dual 7-Segment LED Display easily
shows system operating status codes
and diagnostic codes.
A Sealed Switch replaces the standard
contactor and
features optical
control and
latching mecha-
nism. The sealed
switch prevents
infiltration of
insects and dust. A minimal switching
arc, by the optical control, offers greater
reliability. The latching mechanism con-
sumes less power while reducing chatter.
The Status Indication and System Diagnostics feature
thermostat communication capability, built-in diagnostics,
current sensing and high & low pressure switch monitor-
ing. The thermostat communication capability alerts the
homeowner to any necessary ser-
vice requirements. Faster, more
accurate service is provided by the
built-in diagnostics, by providing
the HVAC professional with
dependable information. In addition,
high and low pressure-switch moni-
toring prevents the system from
operating outside of its normal parameters.
The fault recall feature will allow for the last six fault-codes
to be displayed, and will retain these codes even if power
failure occurs.
Built-in short-cycle protection allows the compressor to
restart easily without oil removal.
A 30-second minimum run-time for every compressor call
allows the oil to return to the compressor.
Active Protection monitors the system to prevent nuisance
lockouts and prevents compressor operation when poten-
tially harmful conditions are detected.
The compressor and fan are
controlled independently,
which reduces the starting load
and light dimming.
A manual push-button is
offered to operate the com-
pressor and fan for 5 seconds
to allow for an operation
check.
In order to save time and
money, replacement automotive fuses can be utilized
instead of replacing the entire control board.
Standard Features:
RASL- JEC Condensing Units
1. Scroll compressor is hermetically sealed and incorporates
internal high temperature motor overload protection, and
durable insulation on the motor windings. It is externally
mounted on rubber grommets to reduce vibration and noise.
2. Compressors have an internal pressure relief assembly to
protect against excessive pressure differential.
3. All refrigerant connections are on the exterior of the unit,
located close to the ground for neat appearing installations.
4. Cabinet is constructed of powder painted galvanized
steel. The full wrap-around louvered grille protects the coil
from damage.
5. Sound Blanket-enhanced compressor sound blanket is
standard.
6. Copper tube—aluminum fin coils are used on all models.
7. The control box is located in the top corner of the cabinet
providing for easy access through a service panel.
8. Service valves are standard on all models.
9. Field connections for power and control wiring are kept
separate.
10. Every unit is factory charged and run-tested.
11. Separate compressor compartment for easy service
access.
12. Drawn, painted base pan for extra corrosion resistance and
sound reduction.
13. The RASL- JEC has a 10-year limited parts warranty, plus a
10-year conditional unit replacement warranty. Refer to the
General Terms of Limited Warranty for more details.
14. Hard Start Kits—Standard on all JEC models.
15. Control Box Cover.
16. The RASL- JEC is shipped with a liquid line filter drier, and
also features factory-installed low and high pressure
controls.
The
Comfort Control
2
System
Features:
Scroll
®
Compressor
024 & 036 nominal capacities
— Single scroll Ultra-Tech two-stage
compressor
— Operates at 67% capacity in non
peak conditions to improve
efficiency and comfort (humidity
control)
039, 048 & 60 nominal capacities
— Dual Drive scroll compressors –
Tandem
— Operates at 50% capacity on first
compressor in non peak conditions
to improve efficiency and comfort
(humidity control)
— Compressor “A” operated by control
board “A” Compressor “B” operated
by control board “B”.
Page view 2