Rheem 2-stage Specifications Sheet

Browse online or download Specifications Sheet for Thermostats Rheem 2-stage. Rheem 2-Stage Specification Sheet [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Rheem Prestige Series
Two-Stage Upflow/Horizontal
Gas Furnace equipped with
The Comfort Control
2
System
FORM NO. G11-512 REV. 1
RGPE- Series
80% A.F.U.E.†
Input Rates 50-125 kBTU
A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with
Department of Energy test procedures.
The Rheem Prestige Series
Two-Stage line of upflow/
horizontal gas furnaces are designed for utility rooms, closets,
alcoves, or attics. Because of the furnace’s low-profile 34
inch [864 mm] height, the upflow model installed vertically
can also be used to satisfy most applications that traditionally
call for a horizontal furnace.
The design is certified by CSA International.
The Comfort Control
2
Systemprovides over 28 on-board
diagnostics and fault history codes by detecting system and
electrical problems. “Call for Service” alert notification is sent
to the thermostat to alert the homeowner of required service.
Serial Communication Enhanced – When installed with a
Serial Com muni cat ing Condensing Unit and user interface
control (RHC-TST550CMMS) 500 Series thermostat this unit
offers 4 or 2 wire installation, auto-configuration, and diag-
nostic messaging with full communicating capability.
Patented heat exchanger, constructed of aluminized steel for the
maximum in corrosion resistance and thermal fatigue reliability.
Low profile “34 inch” [864 mm] design is lighter and easier to
handle, and leaves room for optional equipment.
Energy efficient and quiet ECM 2+ communicating motor.
Improves cooling efficiency when matched with rated
condensing unit and coil.
Constant CFM.
Seven segment LED for system diagnostics.
Diagnostic history for troubleshooting.
Dip switch settings for selectable cooling airflow.
On-demand dehumidification terminal for improved comfort in
cooling mode.
Convertible from upflow to horizontal left or right.
Left or right side gas and electric inlet connections.
All models equipped with flame sensor feature, an integrated
board with humidifier and electronic air cleaner hookups.
Insulated blower compartment, a slow-open gas valve, a
specially designed draft inducer motor and blower motor
make it one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
Molded permanent filter.
Easy door removal and replacement.
Compatible with single or two-stage thermostat. (For optimal
performance, two-stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with
Rheem Prestige Series
Two-Stage gas furnaces are avail-
able as optional accessories.
Air
Gas Furnaces
RGPE Series
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - The Comfort Control

Rheem Prestige Series™Two-Stage Upflow/HorizontalGas Furnace equipped withThe Comfort Control2System™FORM NO. G11-512 REV. 1RGPE- Series80% A.F.U.E.†I

Page 2 - TABLE OF CONTENTS

AirAccessoriesRGPE Series10RETURN AIR CABINETSAIN. [mm]FILTER SIZEIN. [mm]RXGR-C17B 171/2 [445] (2) 12 x 16 [305 x 406]RXGR-C21B211/4 [533](2) 20 x 16

Page 3 - OPTIONAL EQUIPMENT

AirAccessoriesRGPE Series11CONTRACTOR BENEFITS:• Multi-Purpose Thermostat-Setup, Control & Diagnostics• Auto-Configuration – No Manual Settings Re

Page 4 - Comfort Control

AirLimited WarrantyRGPE Series12GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Page 7 - Dimensional Data

AirNotesRGPE Series15

Page 8 - FACING UPWARDS

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Page 9 - Blower Performance Data

AirTable of ContentsRGPE Series2TABLE OF CONTENTSStandard & Optional Equipment ...

Page 10 - RETURN AIR CABINETS

AirStandard & Optional EquipmentRGPE Series3WARNINGTHIS FURNACE IS NOT APPROVEDOR RECOMMENDEDFOR USE IN MOBILE HOMESSTANDARD EQUIPMENTCompletely a

Page 11 - THERMOSTATS

AirModel FeaturesRGPE Series4nThe Rheem Dual 7-Segment LED Display easily showssystem operating status codes and diagnostic codes.nThe Status Indicati

Page 12

AirPhysical Data & SpecificationsRGPE Series5Physical Data and Specifications—Upflow ModelsU.S. and Canadian ModelsMODEL NUMBERSRGPE- SERIES05EBMK

Page 13 - RGPE Series

AirModel Number IdentificationRGPE Series6Model Number Identification—Upflow ModelsG P EFurnaceA M K RRheem Gas Upflow/ Design Heating Input Designati

Page 14

AirDimensional DataRGPE Series7NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.➁ May be 0&qu

Page 15

AirDimensional DataRGPE Series8NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.➁ May be 0&q

Page 16 - The new degree of comfort

AirBlower Performance DataRGPE Series9Blower Performance DataMODEL RGPE-BLOWER SIZE(D X W)INCHES [mm]ECMMOTOR H.P.[W]BLOWERSPEEDCFM [L/s] AIR DELIVERY

Comments to this Manuals